    Vitamin C Intravenous Treatment In the Setting of Atrial Fibrillation Ablation: Results From the Randomized, Double-Blinded, Placebo-Controlled CITRIS-AF Pilot Study

    Get PDF
    BackgroundCatheter ablation is an effective treatment for atrial fibrillation (AF), but high levels of post-procedure inflammation predict adverse clinical events. Ascorbic acid (AA) has shown promise in reducing inflammation but is untested in this population. We sought to test the feasibility, safety, and preliminary effects on inflammatory biomarkers in the CITRIS-AF (Vitamin C Intravenous Treatment In the Setting of Atrial Fibrillation Ablation) pilot study. Methods and ResultsPatients scheduled to undergo AF ablation (N=20) were randomized 1:1 to double-blinded treatment with AA (200 mg/kg divided over 24 hours) or placebo. C-reactive protein and interleukin-6 levels were obtained before the first infusion and repeated at 24 hours and 30 days. Pain levels within 24 hours and early recurrence of AF within 90 days were recorded. Median and interquartile range were aged 63 (56–70) years, 13 (65%) men, and 18 (90%) white. Baseline data were similar between the 2 groups except ejection fraction. Baseline C-reactive protein levels were 2.56 (1.47–5.87) mg/L and similar between groups (P=0.48). Change in C-reactive protein from baseline to 24 hours was +10.79 (+6.56–23.19) mg/L in the placebo group and +3.01 (+0.40–5.43) mg/L in the AA group (P=0.02). Conversely, change in interleukin-6 was numerically higher in the AA group, though not statistically significant (P=0.32). One patient in each arm developed pericarditis; no adverse events related to the infusions were seen. There were no significant differences between aggregated post-procedure pain levels within 24 hours or early recurrence of AF (both P\u3e0.05). ConclusionsHigh-dose AA is safe and well tolerated at the time of AF ablation and may be associated with a blunted rise in C-reactive protein, although consistent findings were not seen in interleukin-6 levels. Further studies are needed to validate these findings and explore the potential benefit in improving clinically relevant outcomes

    Incidence of premature battery depletion in subcutaneous cardioverter-defibrillator patients: insights from a multicenter registry.

    Get PDF
    BACKGROUND The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data. METHODS Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less. RESULTS Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months. CONCLUSIONS The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT04767516

    Clarithromycin, QTc interval prolongation and torsades de pointes:the need to study case reports

    No full text
    BACKGROUND: The manufacturers of clarithromycin sought a drug similar in efficacy to erythromycin but with a superior side-effect profile. They generally achieved this outcome, but postmarketing findings identified a series of reports linking clarithromycin to QTc interval prolongation and torsades de pointes (TdP) ultimately leading to a Black Box Warning. We sought to clarify risk factors associated with TdP among case reports of patients receiving clarithromycin linked to QTc interval prolongation and TdP. METHODS AND RESULTS: In a detailed literature search, we found 15 women, five men, and one boy meeting our search criteria. Among the 17 adults with reported clarithromycin dose and concurrent QTc interval measurement, we found no statistically significant relationship between clarithromycin dose and QTc interval duration. This did not change for the adults who developed TdP. Among adults, major risk factors were female sex (15), old age (11) and heart disease (17). A total of eight adult subjects had all three major risk factors and 14 of the 20 adults had at least two major risk factors. All adult subjects had at least two risk factors besides clarithromycin. A total of four of the 20 adults received cisapride and three received disopyramide. Three adults were considered to suffer from some aspect of the congenital long QT syndrome. CONCLUSIONS: We believe that the risk factor description for this drug should be refined to emphasize the major risk factors of (1) female sex, (2) old age and (3) heart disease

    Permanent His bundle pacing: Recommendations from a Multicenter His Bundle Pacing Collaborative Working Group for standardization of definitions, implant measurements, and follow-up

    No full text
    His bundle pacing (HBP) prevents ventricular dyssynchrony and its long-term consequences by preserving normal electrical activation of the ventricles. Since the original description of permanent HBP in 2000, the adoption of HBP has increased over the past several years. However, the reporting of procedural and clinical outcomes to date is not uniform. This article is a collaboration between several implanters with significant experience in HBP to establish a uniform set of definitions encompassing the different forms of HBP as well as define a standardized approach to gathering data end points to ensure consistency in reported outcomes